    CK18 Torch Parts FAQs

    Spare hoses, power cables, back caps and torch bodies for a water-cooled TIG torch, and how to choose the right ones.

    Why does my water-cooled torch overheat?icon-minus-redicon-plus-red

    Common causes are low coolant flow, a kinked, damaged or blocked hose, a loose or poor connection, welding above the torch's current rating, and worn or non-matching consumables. The lowest-rated part in the torch set-up sets the limit, so check the rating of every part you have fitted.

    Stop welding if the head or cable gets unusually hot. Let it cool, then check the cooler level, look for kinks and damage, and make sure the connectors are clean and tight before restarting. If the cooler has a flow warning, do not bypass it.

    How do I check that coolant is actually flowing?icon-minus-redicon-plus-red

    Check the cooler level before every job and, with the cooler running, look for a firm return flow back into the cooler tank or on its flow indicator. Check again after you change a torch body, hose or cable. Many power sources also give a coolant warning if circulation stops.

    If the flow looks weak, check the level, the hoses for kinks, any filter or strainer for contamination, and the connections. For the minimum flow your torch needs, use the torch and cooler manuals, as it depends on the torch and its rating. Never run a water-cooled torch without coolant.

    How do I replace hoses and cables safely?icon-minus-redicon-plus-red

    Switch off and isolate the power source and the cooler, close the gas supply and let the torch cool first. Maintenance should be done by someone trained and competent. Be ready for some coolant to escape and wipe up spills, since coolant near live equipment is a shock hazard.

    Fit the new parts to the right connections, seal any open coolant hoses while they are disconnected, then refill the cooler and bleed air from the circuit as the manual describes. With coolant circulating and before you strike an arc, check every connection for leaks. Follow the manufacturer's instructions for any specific checks.

    Is argon from the torch a safety risk?icon-minus-redicon-plus-red

    Yes. Argon is colourless, odourless and heavier than air. It can collect in tank bottoms, pits and other low areas, and oxygen-free air can cause unconsciousness within seconds with little warning. Shielding gas can build up quickly inside a fabrication during internal welding.

    Avoid entering confined or possibly confined spaces where you can. Use forced ventilation, test oxygen levels from outside, and follow a safe system of work if entry is unavoidable. Keep hoses and fittings sealed so gas is not leaking, and follow your risk assessment.